Trending: Anna University 8th Sem Results April 2014 May/June 2014 Time Table/ Internal Marks Calculate CGPA Online SSLC Results 2014 12th Result 2014

Test Footer 1

Wednesday, September 12, 2012

EE2259 ELECTRICAL MACHINES LAB SYLLABUS | ANNA UNIVERSITY BE EEE ENGINEERING 4TH SEM SYLLABUS REGULATION 2008 2011 2012-2013

Latest: TNEA 2014 Engineering Application Status, Counselling Date, Rank List
EE2259 ELECTRICAL MACHINES LAB SYLLABUS | ANNA UNIVERSITY BE EEE ENGINEERING 4TH SEM SYLLABUS REGULATION 2008 2011 2012-2013 BELOW IS THE ANNA UNIVERSITY FOURTH SEMESTER BE ELECTRICAL AND ELECTRONICS ENGINEERING DEPARTMENT SYLLABUS, TEXTBOOKS, REFERENCE BOOKS,EXAM PORTIONS,QUESTION BANK,CLASS NOTES, IMPORTANT 2 MARKS, 8 MARKS, 16 MARKS TOPICS. IT IS APPLICABLE FOR ALL STUDENTS ADMITTED IN THE YEAR 2011 2012-2013 (ANNA UNIVERSITY CHENNAI,TRICHY,MADURAI,TIRUNELVELI,COIMBATORE), 2008 REGULATION OF ANNA UNIVERSITY CHENNAI AND STUDENTS ADMITTED IN ANNA UNIVERSITY CHENNAI DURING 2009


EE2259 ELECTRICAL MACHINES LABORATORY – I L T P C
0 0 3 2
AIM
To expose the students to the operation of D.C. machines and transformers and give them
experimental skill.
1. Open circuit and load characteristics of separately and self excited DC shunt generators.
2. Load characteristics of DC compound generator with differential and cumulative connection.
3. Load characteristics of DC shunt and compound motor.
4. Load characteristics of DC series motor.
5. Swinburne’s test and speed control of DC shunt motor.
6. Hopkinson’s test on DC motor – generator set.
7. Load test on single-phase transformer and three phase transformer connections.
8. Open circuit and short circuit tests on single phase transformer.
9. Sumpner’s test on transformers.
10. Separation of no-load losses in single phase transformer.
TOTAL: 45 PERIODS
51
Requirement for a batch of 30 students
S.No. Description of Equipment Quantity
required
Quantity
available
Deficiency
%
1. D.C motor – Generator set
D.C motor – Shunt Generator
D.C motor – Compound Generator
2 set
2 set
2. D.C. Shunt Motor 2 Nos.
3. D.C. Series Motor 1 No.
4. D.C. Compound Motor 1 No.
5. Single phase transformers 7 Nos.
6. Three phase transformers 2 Nos.
7. D.C. Motor – Alternator set 4 sets
8. Three phase Induction Motor (Squirrel cage) 3 Nos.
9. Three phase slip ring Induction Motor 1 No.
10. Single phase Induction Motor 2 Nos.
11. Resistive load
3 phase – 2 , single phase - 3
5 Nos.
12. Inductive load 1 No.
13. Single phase Auto transformer 5 Nos.
14. Three phase Auto transformer 3 Nos.
15. Moving Coil Ammeter of different ranges 20 Nos.
16. Moving Coil Voltmeter of different ranges 20 Nos.
17. Moving Iron Ammeter of different ranges 20 Nos.
18. Moving Iron voltmeter of different ranges 20 Nos.
19. Wire wound Rheostats of different ratings 30 Nos.
20. Tachometers 10 Nos.
21. Single element wattmeters of different ranges 20 Nos.
52
UPF / LPF
22. Double element wattmeters of different ranges 4 Nos.
23. Power factor meter 2 Nos.
24. Digital multimeter 5 Nos.
25. Three point starter, four point starter,DOL starter,
manual star / delta starter, semi automatic and fully
automatic star / delta starter
1 No each
for study
experiment

No comments:

Post a Comment