Trending: Anna University 8th Sem Results April 2014 May/June 2014 Time Table/ Internal Marks Calculate CGPA Online SSLC Results 2014 12th Result 2014

Test Footer 1

Thursday, September 13, 2012

EC 2259 ELECTRICAL ENGINEERING AND CONTROL SYSTEM LAB SYLLABUS | ANNA UNIVERSITY BE ECE ENGINEERING 4TH SEM SYLLABUS REGULATION 2008 2011 2012-2013

Latest: TNEA 2014 Engineering Application Status, Counselling Date, Rank List
EC 2259 ELECTRICAL ENGINEERING AND CONTROL SYSTEM LAB SYLLABUS | ANNA UNIVERSITY BE ECE ENGINEERING 4TH SEM SYLLABUS REGULATION 2008 2011 2012-2013 BELOW IS THE ANNA UNIVERSITY FOURTH SEMESTER BE ELECTRONICS AND COMMUNICATION ENGINEERING DEPARTMENT SYLLABUS, TEXTBOOKS, REFERENCE BOOKS,EXAM PORTIONS,QUESTION BANK,CLASS NOTES, IMPORTANT 2 MARKS, 8 MARKS, 16 MARKS TOPICS. IT IS APPLICABLE FOR ALL STUDENTS ADMITTED IN THE YEAR 2011 2012-2013 (ANNA UNIVERSITY CHENNAI,TRICHY,MADURAI,TIRUNELVELI,COIMBATORE), 2008 REGULATION OF ANNA UNIVERSITY CHENNAI AND STUDENTS ADMITTED IN ANNA UNIVERSITY CHENNAI DURING 2009


EC 2259 ELECTRICAL ENGINEERING AND CONTROL SYSTEM LAB L T P C
0 0 3 2
AIM
46
1. To expose the students to the basic operation of electrical machines and help them
to develop experimental skills.
2. To study the concepts, performance characteristics, time and frequency response of
linear systems.
3. To study the effects of controllers.
4. Open circuit and load characteristics of separately excited and self excited D.C.
generator.
5. Load test on D.C. shunt motor.
6. Swinburne’s test and speed control of D.C. shunt motor.
7. Load test on single phase transformer and open circuit and short circuit test on
single phase transformer
8. Regulation of three phase alternator by EMF and MMF methods.
9. Load test on three phase induction motor.
10. No load and blocked rotor tests on three phase induction motor (Determination of
equivalent circuit parameters)
11. Study of D.C. motor and induction motor starters.
12. Digital simulation of linear systems.
13. Stability Analysis of Linear system using Mat lab.
14. Study the effect of P, PI, PID controllers using Mat lab.
15. Design of Lead and Lag compensator.
16. Transfer Function of separately excited D.C.Generator.
17. Transfer Function of armature and Field Controller D.C.Motor.
TOTAL = 45 PERIODS
1. Open circuit and load characteristics of separately excited and self excited
D.C. generator.
Sl. No. Apparatus Range
Quantity
1 Motor Generator set - 1
2 Rheostat 200, 5A
175, 1.5A
1
2
3 Voltmeter DC 300V
30V
1
1
4 Ammeter DC 30A
2A
1
2
5 DPST switch 2
6 Three point starter 1
7 Tachometer 1
2. Load test on D.C. shunt motor.
Sl. No. Apparatus Range Quantity
1 DC Motor - 1
47
2 Rheostat 175, 1.5A 1
3 Voltmeter DC 300V 1
4 Ammeter DC 30A 1
5 DPST switch 1
6 Three point starter 1
7 Tachometer 1
3. Swinburne’s test and speed control of D.C. shunt motor
Sl. No. Apparatus Range Quantity
1 DC Motor - 1
2 Rheostat 100, 5A
175, 1.5A
1
1
3 Voltmeter DC 300V 1
4 Ammeter DC 5A
2A
1
1
5 DPST switch 1
6 Tachometer 1
4. Load test on single-phase transformer and open circuit and short circuit
test on single-phase transformer.
Sl. No. Apparatus Range Quantity
1 Single phase Transformer - 1
2 Wattmeter 300V, 5A,UPF
300V, 5A,LPF
1
1
3 Voltmeter AC 300V 2
4 Ammeter AC 5A
30A
1
1
5 Single phase auto-transformer 1
6 Resistive load 1
5. Regulation of three-phase alternator by EMF and MMF method.
Sl. No. Apparatus Range Quantity
1 Motor Alternator set - 1
2 Rheostat 200, 5A
175, 1.5A
1
1
3 Voltmeter DC
Voltmeter AC
300V
600V
1
1
4 Ammeter DC
Ammeter AC
2A
30A
1
1
5 DPST switch
TPST switch
1
1
6 Tachometer 1
6. Load test on three phase Induction motor.
Sl. No. Apparatus Range Quantity
1 Three Phase Induction Motor - 1
48
2 Wattmeter 600V, 10A,UPF 2
3 Voltmeter AC 600V 1
4 Ammeter AC 10A 1
5 Brake drum arrangement
6 Star delta starter 1
7 Tachometer 1
7. No load and blocked rotor test on three-phase induction motor
(Determination of equivalent circuit parameters)
Sl. No. Apparatus Range Quantity
1 Three Phase Induction Motor - 1
2 Wattmeter 600V, 10A,UPF
600V, 5A,LPF
2
2
3 Voltmeter AC 600V
150V
1
1
4 Ammeter AC 10A
5A
1
1
5 Brake drum arrangement
6 Three phase auto-transformer 1
8. Study of D.C. motor and Induction motor starters.
Sl. No. Apparatus Quantity
1 Three point starter 1
2 Four point starter 1
3 Star-delta starter 1
4 DOL starter 1
5 Three phase auto-transformer 1
9. Digital simulation of linear systems.
Simulink software for minimum 3 users license
10. Stability analysis of linear system using Mat lab.
Matlab software for minimum 3 users license
11. Study of effect of P, PI, PID controllers using Mat lab.
Matlab software for minimum 3 users license
12. Design of lead and lag compensator.
Sl. No. Apparatus
1 Resistor
2 Capacitor
49
3 Function generator
4 Bread Board
13. Transfer function of separately excited D.C. generator.
Sl. No. Apparatus Range
Quantity
1 Motor Generator set - 1
2 Rheostat 200, 5A
175, 1.5A
1
2
3 Voltmeter DC 300V
30V
1
1
4 Ammeter DC 30A
2A
1
2
5 DPST switch 2
6 Three point starter 1
7 Tachometer 1
14. Transfer function of armature and field controller D.C. motor.
Sl. No. Apparatus Range
Quantity
1 DC Motor - 1
2 Rheostat 175, 1.5A 1
3 Voltmeter DC 300V 1
4 Ammeter DC 30A 1
5 DPST switch 1
6 Three point starter 1
7 Tachometer 1