AR2304 BUILDING SERVICES III SYLLABUS | ANNA UNIVERSITY B.ARCH 5TH SEMESTER SYLLABUS REGULATION 2008 2011 2012-2013 BELOW IS THE ANNA UNIVERSITY FIFTH SEMESTER B.ARCH DEPARTMENT SYLLABUS, TEXTBOOKS, REFERENCE BOOKS, IT IS APPLICABLE FOR ALL STUDENTS ADMITTED IN THE YEAR 2011 2012-2013 (ANNA UNIVERSITY CHENNAI,TRICHY,MADURAI,TIRUNELVELI,COIMBATORE), 2008 REGULATION OF ANNA UNIVERSITY CHENNAI AND STUDENTS ADMITTED IN ANNA UNIVERSITY CHENNAI DURING 2009
AR2304 BUILDING SERVICES III L T P/S C
3 0 0 3
AIM:
To familiarize the students with building services that support the functioning of a building in the
area of internal environment control and fire and security systems.
OBJECTIVES:
To expose the students to the science behind an air-conditioning and refrigeration system.
To familiarize them with the various air- conditioning systems and their applications.
To study the design issues for the selection of various systems and their installation
To inform of the various ways by which fire safety design can be achieved in buildings
through passive design.
To familiarize the students with the various fire fighting equipment and their installation.
CONTENT:
35
UNIT I AIR CONDITIONING: BASIC REFRIGERATION PRINCIPLES 9
Thermodynamics – Heat – Temperature – Latent heat of fusion – evaporation, saturation
temperature, pressure temperature relationship for liquid refrigerants, refrigeration cycle
components – vapor compression cycle – compressors – evaporators – Refrigerant control
devices – electric motors – Air handling Units – cooling towers
UNIT II AIR CONDITIONING: SYSTEMS AND APPLICATIONS 12
Air conditioning system for small buildings – window types, evaporative cooler, packaged
terminal units and through the wall units split system
b) Systems for large building – Chilled water plant – All Air system, variable air volume, All water
system
Configuring/ sizing of mechanical equipment, equipment spaces and sizes for chiller plant,
cooling tower, Fan room, Circulation Pumps, Pipes, ducts
UNIT III AIR CONDITIONING: DESIGN ISSUES AND HORIZONTAL
DISTRIBUTION OF SYSTEMS 6
Design criteria for selecting the Air conditioning system for large building and energy
conservation measures - Typical choices for cooling systems for small and large buildings -
Horizontal distribution of services for large buildings - Grouped horizontal distribution over
central corridors, Above ceiling, In floor, Raised access floor, Horizontal distribution of
mechanical services
UNIT IV FIRE SAFETY: DESIGN AND GENERAL
GUIDELINES OF EGRESS DESIGN 10
Principles of fire behavior, Fire safety design principles _ NBC Planning considerations in
buildings – Non- Combustible materials, egress systems, Exit Access – Distance between exits,
exterior corridors – Maximum travel distance, Doors, Smoke proof enclosures
General guidelines for egress design for Auditoriums, concert halls, theatres, other building
types, window egress, accessibility for disabled- NBC guidelines – lifts lobbies, stairways, ramp
design, fire escapes and A/C, electrical systems.
UNIT V FIRE SAFETY: FIRE DETECTION AND FIRE FIGHTING INSTALLATION 8
Heat smoke detectors – sprinkler systems
Fire fighting pump and water requirements, storage – wet risers, Dry rises
Fire extinguishers & cabinets
Fire protection system – CO2 & Halon system
Fire alarm system, snorkel ladder
Configuring, sizing and space requirements for fire fighting equipments
TOTAL: 45 PERIODS
REQUIRED READINGS:
1. William H.Severns and Julian R Fellows, Air conditioning and Refrigeration, John Wiley and
Sons, London, 1988
2. Fire Safety: nAtional Building Code of India 1983 published by Bureau of Indian
Standards…
REFERENCES:
1. A.F.C. Sherratt, Air conditioning and Energy conservation, The Architectural Press,
London, 1980
2. Design for fire safety (Andrew H Buchanan, John Wiley & Sons Ltd., New York)
AR2304 BUILDING SERVICES III L T P/S C
3 0 0 3
AIM:
To familiarize the students with building services that support the functioning of a building in the
area of internal environment control and fire and security systems.
OBJECTIVES:
To expose the students to the science behind an air-conditioning and refrigeration system.
To familiarize them with the various air- conditioning systems and their applications.
To study the design issues for the selection of various systems and their installation
To inform of the various ways by which fire safety design can be achieved in buildings
through passive design.
To familiarize the students with the various fire fighting equipment and their installation.
CONTENT:
35
UNIT I AIR CONDITIONING: BASIC REFRIGERATION PRINCIPLES 9
Thermodynamics – Heat – Temperature – Latent heat of fusion – evaporation, saturation
temperature, pressure temperature relationship for liquid refrigerants, refrigeration cycle
components – vapor compression cycle – compressors – evaporators – Refrigerant control
devices – electric motors – Air handling Units – cooling towers
UNIT II AIR CONDITIONING: SYSTEMS AND APPLICATIONS 12
Air conditioning system for small buildings – window types, evaporative cooler, packaged
terminal units and through the wall units split system
b) Systems for large building – Chilled water plant – All Air system, variable air volume, All water
system
Configuring/ sizing of mechanical equipment, equipment spaces and sizes for chiller plant,
cooling tower, Fan room, Circulation Pumps, Pipes, ducts
UNIT III AIR CONDITIONING: DESIGN ISSUES AND HORIZONTAL
DISTRIBUTION OF SYSTEMS 6
Design criteria for selecting the Air conditioning system for large building and energy
conservation measures - Typical choices for cooling systems for small and large buildings -
Horizontal distribution of services for large buildings - Grouped horizontal distribution over
central corridors, Above ceiling, In floor, Raised access floor, Horizontal distribution of
mechanical services
UNIT IV FIRE SAFETY: DESIGN AND GENERAL
GUIDELINES OF EGRESS DESIGN 10
Principles of fire behavior, Fire safety design principles _ NBC Planning considerations in
buildings – Non- Combustible materials, egress systems, Exit Access – Distance between exits,
exterior corridors – Maximum travel distance, Doors, Smoke proof enclosures
General guidelines for egress design for Auditoriums, concert halls, theatres, other building
types, window egress, accessibility for disabled- NBC guidelines – lifts lobbies, stairways, ramp
design, fire escapes and A/C, electrical systems.
UNIT V FIRE SAFETY: FIRE DETECTION AND FIRE FIGHTING INSTALLATION 8
Heat smoke detectors – sprinkler systems
Fire fighting pump and water requirements, storage – wet risers, Dry rises
Fire extinguishers & cabinets
Fire protection system – CO2 & Halon system
Fire alarm system, snorkel ladder
Configuring, sizing and space requirements for fire fighting equipments
TOTAL: 45 PERIODS
REQUIRED READINGS:
1. William H.Severns and Julian R Fellows, Air conditioning and Refrigeration, John Wiley and
Sons, London, 1988
2. Fire Safety: nAtional Building Code of India 1983 published by Bureau of Indian
Standards…
REFERENCES:
1. A.F.C. Sherratt, Air conditioning and Energy conservation, The Architectural Press,
London, 1980
2. Design for fire safety (Andrew H Buchanan, John Wiley & Sons Ltd., New York)
No comments:
Post a Comment
Any doubt ??? Just throw it Here...